De Thermistorsonde van pvc Overmolded 10KΩ 3950K 6.5x25mm NTC
Productdetails:
Merknaam: | Aolittel |
Modelnummer: | CWFM0103FC1-202M113X |
Betalen & Verzenden Algemene voorwaarden:
Min. bestelaantal: | 1000 stukken |
---|---|
Prijs: | Negotiable |
Verpakking Details: | Massa |
Levertijd: | 2-4 weken |
Betalingscondities: | T/T |
Levering vermogen: | 1.000.000 Stukken per Maand |
Gedetailleerde informatie |
|||
Artikelnaam: | Vloer de Verre van de Micro- Sonde Temperatuursensor | R25: | 10KΩ±1% |
---|---|---|---|
B25/50: | 3950K±1% | Sondediameter: | 6.5mm |
Sondelengte: | 20mm | Temperaturenwaaier: | -30~+105C |
Het weerstaan van Voltage: | 1500VAC 2Sec | Reactiesnelheid: | 15sec |
Hoog licht: | 25mm de sonde van de ntcthermistor,de thermistorsonde van 3950K ntc,25mm de sensor van ntctemperaturen |
Productomschrijving
De Thermistorsonde van pvc Overmolded 10KΩ 3950K 6.5x25mm NTC
De Zaal van pvc Overmolded de Verre van de Micro- van Undefloor van de Thermostaat Verwarmende Verwarmingskabel Sonde 10KΩ 3950K 6.5x25mm Temperatuursensor
Overzicht
De Sonde en de Sensor worden gebruikt om temperatuur te controleren waar de vochtigheid een probleem d.w.z. in natte ruimte of badkamers zou zijn. Het kan vloertemperatuur ook controleren waar het oververhitten schade zou veroorzaken.
____________________________________________________________________________Download______
Materialen
Nr | Materiële Naam | Materiaal en Specificaties |
1. | Element | R25=10KΩ±1% B25/50=3950K±1% GELIJKSTROOM |
2. | Deklaag | Ingekapselde NTC gebruikend pvc-(Wit) over--vormmateriaal |
3 | Kabeleigenschappen |
UL2464-22AWG tin geplateerde koperkabel met witte vlakke het jasjedraad 80℃ 300V van pvc
|
4. | Draadeinden | Ingeblikt |
Afmeting | ||||
A | B | C | D | L |
6.5 | 20 | 25±5 | 3±1 | zonodig |
Prestaties
Nr | Punt | Teken | Beproevingsomstandigheden | Min. | Noch. | Max. | Eenheid |
1. | Weerstand bij 25℃ | R25 |
Ta=25±0.05℃ PT ≦0.1mw |
9.9 | 10.0 | 10.1 | kΩ |
2. | B Waarde | B25/50 | 3910.5 | 3950 | 3989.5 | k | |
3. | Dissipatiefactor | σ | In nog lucht | Ongeveer 2 | mW/℃ | ||
4. | Tijdreactie | τ | In stromend water | Ongeveer 15 | seconde | ||
5. | Het weerstaan van Voltage | / | 1500VAC 2Sec | Geen analyse | Seconde | ||
6. | Isolatieweerstand | 500VDC | ≧100 | MΩ | |||
7. | Werkende temperaturen. waaier | / | / | -30 | / | +105 | ℃ |
Droog & Stevige Muur Instalation
De tweeling-Leider van de Mincohitte 0.5M2 Elektrische Vloerverwarming Mats For Warm Floor, Vloerverwarmingsuitrustingen
Weerstand versus Temperatuurlijst
RECHTS-OMREKENINGSTABEL | ||||||||
R25=10KΩ±1%B25/50=3950K±1% | ||||||||
T/℃ | Rmin | Rcen | Rmax | T/℃ | Rmin | Rcen | Rmax | |
-40 | 335,811 | 351,495 | 367,875 | -5 | 41,735 | 42,774 | 43,834 | |
-39 | 314,029 | 328,472 | 343,546 | -4 | 39,599 | 40,563 | 41,547 | |
-38 | 293,803 | 307,110 | 320,988 | -3 | 37,586 | 38,480 | 39,392 | |
-37 | 275,015 | 287,279 | 300,060 | -2 | 35,686 | 36,517 | 37,363 | |
-36 | 257,552 | 268,859 | 280,635 | -1 | 33,894 | 34,665 | 35,450 | |
-35 | 241,313 | 251,741 | 262,595 | 0 | 32,203 | 32,919 | 33,646 | |
-34 | 226,204 | 235,826 | 245,832 | 1 | 30,607 | 31,270 | 31,945 | |
-33 | 212,141 | 221,021 | 230,250 | 2 | 29,099 | 29,715 | 30,340 | |
-32 | 199,044 | 207,242 | 215,757 | 3 | 27,674 | 28,246 | 28,826 | |
-31 | 186,841 | 194,412 | 202,270 | 4 | 26,328 | 26,858 | 27,396 | |
-30 | 175,465 | 182,460 | 189,714 | 5 | 25,055 | 25,547 | 26,045 | |
-29 | 164,856 | 171,320 | 178,019 | 6 | 23,851 | 24,307 | 24,769 | |
-28 | 154,957 | 160,932 | 167,120 | 7 | 22,712 | 23,135 | 23,563 | |
-27 | 145,716 | 151,241 | 156,959 | 8 | 21,634 | 22,026 | 22,423 | |
-26 | 137,086 | 142,196 | 147,481 | 9 | 20,614 | 20,977 | 21,345 | |
-25 | 129,022 | 133,750 | 138,636 | 10 | 19,650 | 19,987 | 20,327 | |
-24 | 121,485 | 125,859 | 130,378 | 11 | 18,733 | 19,044 | 19,359 | |
-23 | 114,435 | 118,485 | 122,665 | 12 | 17,865 | 18,154 | 18,445 | |
-22 | 107,840 | 111,589 | 115,457 | 13 | 17,043 | 17,310 | 17,579 | |
-21 | 101,667 | 105,139 | 108,718 | 14 | 16,264 | 16,510 | 16,759 | |
-20 | 95,886 | 99,102 | 102,415 | 15 | 15,524 | 15,752 | 15,982 | |
-19 | 90,471 | 93,450 | 96,518 | 16 | 14,823 | 15,034 | 15,246 | |
-18 | 85,395 | 88,156 | 90,997 | 17 | 14,157 | 14,352 | 14,548 | |
-17 | 80,636 | 83,195 | 85,826 | 18 | 13,525 | 13,705 | 13,885 | |
-16 | 76,173 | 78,544 | 80,982 | 19 | 12,925 | 13,090 | 13,257 | |
-15 | 71,984 | 74,183 | 76,441 | 20 | 12,354 | 12,507 | 12,660 | |
-14 | 68,052 | 70,091 | 72,184 | 21 | 11,813 | 11,953 | 12,094 | |
-13 | 64,359 | 66,250 | 68,189 | 22 | 11,298 | 11,427 | 11,557 | |
-12 | 60,889 | 62,643 | 64,441 | 23 | 10,808 | 10,927 | 11,046 | |
-11 | 57,628 | 59,255 | 60,922 | 24 | 10,342 | 10,452 | 10,561 | |
-10 | 54,562 | 56,071 | 57,617 | 25 | 9,900 | 10,000 | 10,100 | |
-9 | 51,677 | 53,078 | 54,511 | 26 | 9,470 | 9,570 | 9,670 | |
-8 | 48,963 | 50,263 | 51,592 | 27 | 9,061 | 9,161 | 9,260 | |
-7 | 46,408 | 47,614 | 48,847 | 28 | 8,672 | 8,771 | 8,871 | |
-6 | 44,002 | 45,121 | 46,264 | 29 | 8,302 | 8,401 | 8,499 | |
RECHTS-OMREKENINGSTABEL | ||||||||
R25=10KΩ±1%B25/50=3950K±1% | ||||||||
T/℃ | Rmin | Rcen | Rmax | T/℃ | Rmin | Rcen | Rmax | |
30 | 7,950 | 8,048 | 8,146 | 67 | 1,881 | 1,932 | 1,984 | |
31 | 7,615 | 7,712 | 7,809 | 68 | 1,817 | 1,866 | 1,917 | |
32 | 7,295 | 7,391 | 7,488 | 69 | 1,754 | 1,803 | 1,852 | |
33 | 6,991 | 7,086 | 7,182 | 70 | 1,695 | 1,742 | 1,790 | |
34 | 6,702 | 6,795 | 6,890 | 71 | 1,637 | 1,684 | 1,731 | |
35 | 6,425 | 6,518 | 6,612 | 72 | 1,582 | 1,627 | 1,674 | |
36 | 6,162 | 6,254 | 6,346 | 73 | 1,529 | 1,573 | 1,619 | |
37 | 5,911 | 6,001 | 6,092 | 74 | 1,478 | 1,521 | 1,566 | |
38 | 5,672 | 5,761 | 5,850 | 75 | 1,429 | 1,471 | 1,515 | |
39 | 5,443 | 5,531 | 5,619 | 76 | 1,382 | 1,423 | 1,466 | |
40 | 5,225 | 5,311 | 5,398 | 77 | 1,336 | 1,377 | 1,419 | |
41 | 5,017 | 5,102 | 5,188 | 78 | 1,293 | 1,332 | 1,373 | |
42 | 4,818 | 4,902 | 4,986 | 79 | 1,251 | 1,289 | 1,329 | |
43 | 4,628 | 4,710 | 4,794 | 80 | 1,210 | 1,248 | 1,287 | |
44 | 4,447 | 4,528 | 4,609 | 81 | 1,171 | 1,208 | 1,246 | |
45 | 4,274 | 4,353 | 4,433 | 82 | 1,134 | 1,170 | 1,207 | |
46 | 4,108 | 4,186 | 4,265 | 83 | 1,098 | 1,133 | 1,170 | |
47 | 3,950 | 4,026 | 4,104 | 84 | 1,063 | 1,097 | 1,133 | |
48 | 3,799 | 3,874 | 3,950 | 85 | 1,029 | 1,063 | 1,098 | |
49 | 3,654 | 3,728 | 3,802 | 86 | 0,997 | 1,030 | 1,064 | |
50 | 3,515 | 3,588 | 3,661 | 87 | 0,966 | 0,998 | 1,032 | |
51 | 3,383 | 3,454 | 3,526 | 88 | 0,936 | 0,968 | 1,000 | |
52 | 3,256 | 3,326 | 3,396 | 89 | 0,907 | 0,938 | 0,970 | |
53 | 3,135 | 3,203 | 3,272 | 90 | 0,879 | 0,909 | 0,941 | |
54 | 3,019 | 3,085 | 3,153 | 91 | 0,852 | 0,882 | 0,912 | |
55 | 2,907 | 2,973 | 3,039 | 92 | 0,826 | 0,855 | 0,885 | |
56 | 2,801 | 2,865 | 2,930 | 93 | 0,801 | 0,829 | 0,859 | |
57 | 2,699 | 2,761 | 2,825 | 94 | 0,777 | 0,805 | 0,833 | |
58 | 2,601 | 2,662 | 2,724 | 95 | 0,753 | 0,781 | 0,809 | |
59 | 2,507 | 2,567 | 2,628 | 96 | 0,731 | 0,758 | 0,785 | |
60 | 2,417 | 2,476 | 2,535 | 97 | 0,709 | 0,735 | 0,762 | |
61 | 2,330 | 2,388 | 2,447 | 98 | 0,688 | 0,714 | 0,740 | |
62 | 2,248 | 2,304 | 2,361 | 99 | 0,668 | 0,693 | 0,719 | |
63 | 2,168 | 2,223 | 2,280 | 100 | 0,648 | 0,673 | 0,698 | |
64 | 2,092 | 2,146 | 2,201 | 101 | 0,629 | 0,653 | 0,678 | |
65 | 2,019 | 2,072 | 2,126 | 102 | 0,611 | 0,635 | 0,659 | |
66 | 1,949 | 2,000 | 2,053 | 103 | 0,593 | 0,616 | 0,640 |
Wat is de sonde van de vloersensor en hoe werkt het?
Elke aolittel elektrische vloerverwarmingsthermostaat zou moeten worden gevormd om een sonde van de in-vloersensor te gebruiken om de temperatuur van de vloer te controleren. Dit is de nauwkeurigste manier om de lopende temperaturen te controleren en positief uw energierekeningen te beïnvloeden.
De sensorsonde is 3m snakt, dikke 4mm en zou moeten binnen een buis, in een groef in de vloer of isolatieraad worden gelegd. U kunt de sensorkabel (een 0.75mm tweeling flex die kern gebruiken) door maximaal 50m uitbreiden.
De buis heeft een diameter van 11mm en zou moeten worden gebruikt om verwijdering of vervanging indien nodig te vergemakkelijken.
De sensorsondes zouden altijd in een duidelijk gebied van de vloer (de interne deuropeningen zijn een goede vlek) vanaf een andere hete of koude invloed zoals warm waterpijpen of grote verglaasde verhogingen en nooit onder een deken moeten worden geïnstalleerd! De dekens doen dienst als isolatie die, die de hitte in de vloer houden en de temperatuur opheffen.
Als u de sensorsonde met een deken behandelt zal de rest van de vloer koud blijven omdat de thermostaat het heetste deel van de slechts vloer controleert.
De daadwerkelijke sensor is binnen de module op het eind van de kabel en werkt door de temperatuur van de vloer constant te controleren.
Het temperatuurgegeven wordt teruggestuurd naar de thermostaat die, wanneer het werken aan een vooraf ingesteld programma, automatisch uw gewenste vloertemperatuur handhaaft.
3 uiteinden voor het Installeren van een Vloersensor